1. hydrotechnik

    CAN Pressure sensor

    Hydrotechnik in china
    CAN Pressure sensor data download

    CAN Pressure sensor technical data

    Overload range 2 x nominal pressure
    Burst pressure 3 x nominal pressure
    Signal type CANopen, digital
    Supply voltage Ub
    ... at 4 ... 20 mA 12 ... 27 VDC
    ... at 0 ... 10 VDC -
    Current consumption 10 ... 30 mA, depends on CAN bus load
    Overvoltage protection ± 40 VDC
    Error limit (of fi nal value) comprises the infl uences non-linearity, hysterese, repeatability, zero-point- and span error
    ... at +22 °C (room temperature) ±0.5%
    ... at -15 ... +85°C ±0.5%
    ... at +85 ... +100°C ± 1.0 %
    ... at -40 ... -15°C ± 1.0 %
    Compensation temperature range -15 ... +85 °C
    Non-linearity < ± 0.2 % of final value
    Reproducability < ± 0.1 % of final value
    Hysterese < ± 0.1 % of final value
    Long-term stability < ± 0.1 % of final value/year
    Response time < = 1 ms (10 ... 90 %)
    Frequency range < = 1 kHz
    Isolation resistance min. 100 MOhm
    Total resistance RG = (Ub -10 V) / 20 mA (at output signal 4 ... 20 mA)
    Load resistance RL = > 5 kOhm (at output signal 0 ... 10 VDC)
    Number of load cycles > 1 x 107
    Medium temperature -40 ... +105 °C
    Environmental temperature -40 ... +105 °C
    Storage temperature -40...+125
    EMV test EN 50081-2 and EN 50082-2
    Vibrational stability IEC 68-2-6 and IEC 68-2-36, 20 g
    Shock stability 50 g (11 ms half-sine)
    Electrical measuring connector 5 pole device connector, M12 x 1
    Mechanical connection thread ISO228-G1/4A
    Sealing material profi le seal ring acc. to DIN 3869, FKM
    Protection type (EN 60529 / IEC 529) IP 67 (with screwed connector)
    Casing material non-corrosive high-grade steel
    Membrane material non-corrosive high-grade steel
    Tightening torque 40 Nm (± 5 Nm)
    Weight ~ 100 g
    CAN bus LSS slave function
    Baud rate 10 ... 500 kBaud (settable)
    CAN interface acc. to DIN 11898

    Hydrotechnik CAN Pressure sensor Electrical connector

    Pin assignment CANopen
    1 CAN_SHLD
    2 CAN_V+
    3 CAN_GND
    4 CAN_H
    5 CAN_L
    MINIMESS® direct connector for CAN pressure sensors
    Execution Pressure sensor Pmax Order number
    Direct conn. straight – 1620 CAN 63MPa 2103-07-18.62
    Direct connector 90° – 1620 CAN 63MPa 2146-13-05.00
    Hydrotechnik CAN pressure sensors
    Measuring range(MPa) Measuring range(Bar) CANopen
    0 ... 10 0 ... 100 3403-16-D2.60
    0 ... 40 0 ... 400 3403-15-D2.60
    0 ... 60 0 ... 600 3403-18-D2.60
    HT-PD Related products
     